225W (10CFM forced air) 140W (natural convection) Ratings are inclusive of aux output power
Turn-on Delay:
< 1 second @ 85VAC
Output Voltage Tolerance:
± 2.0% (worst case, set point + load/line regulation)
Load Regulation:
± 0.5% (measured at connector)
Line Regulation:
± 0.2% (measured at connector)
Ripple:
1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)
Transient Response:
<5% deviation (with 25% load step), recovery to within 1% in 1ms
Startup Overshoot:
<5% (full load)
Hold-up Time:
10ms min. (full load)
Aux Output Voltage Regulation:
12V ± 2V (10V min. / 14V max.), for 0A ≤ IAux ≤1.2A
Aux regulation guaranteed when main output power ≥ 15% of 225W rating (~34W).
For main output power < 15%, aux output voltage may drop to < 50% of nominal rating, depending on aux output load. Please check with your system. For main output = 12V, aux output voltage is same as main output.
Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:
Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:
EN61000-3-2, Class A
Voltage Fluctuations/Flicker:
EN61000-3-3
Electrostatic Discharge (ESD) Immunity:
EN61000-4-2, 10KV contact discharge, 20KV air discharge (applied to input or output terminals)
Radiated RF Immunity:
EN61000-4-3, 20V/m 80-2700MHz, 80% 1KHz AM, 80% 5Hz AM
EFT/Burst Immunity:
EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:
EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:
EN61000-4-6, 3VRMS, (6VRMS in ISM/amateur bands), 80% 1KHz AM
Power Frequency Magnetic Field Immunity:
EN61000-4-8, 30A/m
Voltage Dip Immunity:
EN61000-4-11
Mechanical Formats
GTM962250P:
Open-frame No suffix: 2" x 4" style, 101.6*50.8*30.0mm, 170g -C suffix: 3" x 5" style, 127.0*64.8*30.0mm, 180g -D suffix: 4.22" x 7" style, 177.8*107.2*30.0mm, 190g
GTM962251P:
L-frame: 103.5*62.3*40.0mm, 230g
GTM962252P:
Cage: 103.5*62.3*40.0mm, 250g
Note 1:
The open-frame format meets the above EMC specifications as a standalone unit. However, an L-frame or cage version may help to further improve EMI performance, or to help address other system level electrical/mechanical requirements.
Input/Output Connectors
Earth Terminal (J0):
Connector on PCB: Kang Yang PCH250 (0.250" x 0.031" Faston) Recommended mate: TE Connectivity/AMP 2-520184-2 Note: Leave earth terminal disconnected for Class II input
Custom lengths, construction, cable types, ferrites, filters, and termination available upon request.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
Medical 4th Ed.
EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
Attention Mark / Refer to operating manual for operating and service instructions
No Logo Applicable
CB for IEC 60601-1:2005 (Third Edition) + CORR. 1 (2006) + CORR. 2
(2007) + AM1 (2012) or IEC 60601-1 (2012 reprint) (Ed 3.1) up to 48V only
No Logo Applicable
CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
No Logo Applicable
CB for IEC 62368-1:2014 (Second Edition)
CCC GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
CE Certification
Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [UL
62368-1:2014 Ed.2]
Audio/Video, Information And Communication Technology Equipment - Part 1: Safety Requirements [CSA
C22.2#62368-1:2014 Ed.2]
CHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
Medical Elec. Equip.- Part 1-11: Gen. Req. For Basic Safety & Essential Perf.- Collateral Standard - Req.
For Medical Elec. Equip. & Medical Elec. Systems Used In The Home Healthcare Environment [IEC 60601-
1-11:2015 Ed.2]
Indoor Use Only - Mark is on the label or Molded in the case
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
Japan: Voluntary Control Council for Interference (VCCI)
WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm)
Mark is on the label or Molded in the case
Popular Products (Stock items)
SKU
Volts Out
Current Out (Amps)
Connector
RFQ
Sample Request
Vad är en open frame eller intern AC/DC strömförsörjning ?
Open frame AC/DC strömförsörjningar är ochså känd som
AC/DC omvandlare och är en typ intern strömförsörjning.
Open frame strömförsörjningen är byggd in i produkten som önskas
få ström och användas till att mvandla AC ström till DC spänning, Vad är ett IEC 62368-1 : 2018 power supply ?
IEC 62368-1 : 2018 användas till säkerhet för elektriska och
elektroniska apparater angående audio, video, information och
kommunikationsteknologi, business- och kontormaskiner med en
graderad spänning som ej överstiger 600V.
Detta är en produktsäkerhetsstandard som klassifiserar
energikällor, föreskrivna skydd mot dessa energikällor
och ger information vid användning av- och krav till dessa
skydd.
Föreskrivna skyddskrav är menade för att minska
sannolikhet för smärta, injurier och i fall av brand och egendom
skador.
Et IEC 62368 godkänd AC/DC power supply, är ett adapter
som är testad och auktoriserad enligt bestämda standard.
Ersätter ett IEC 62369-1 godkänd power supply ett IEC 60950-1
godkänd power supply ? 20 december 2020 är säkerhets-
standardene IEC 60950-1 och IEC 60065 historia och ersättes
av IEC 62368-1angående tekniska - och audio video produkter.
I nord-Amerika vill ETL och UL 60950-1 godkanningar
fortfarande existera och vill antagligen användas ytterligare. Vad är Level VI effektivitet ?
Nummer I till VI är en international effektmärkeprotokoll
som tillåter producenter att designa effektivitetsnivået av ett
produkt. Detta är baserad på mätningar av energieffektiviteten
och konsumtion vid no load av externa AC/DC adaptrar eller
power supply som testas vid olika lastnivåer. No Load
konsumptionen refererar till konsumption som ett externt power
supply konsumerar även om produktet som önskas strömförsörjad
är avstängd eller koplat av.
Är Level VI ett krav ?
Level VI effektivitet är obligatorisk i många länder och regioner
för särskilda produkter och applikationer.
Vad är ECO Design Directive 2009/125/EC ?
ECO . Design Direktivet är lagstadgad i Europa i dom senaste
energikrav för bevarande av AC/DC adaptrar och externa
power. Hur fungerar ett AC/DC adapter ?
AC/DC adapteren eller exsternt power supply är bestående av ett
power supply som är skyddad i ett plasthus motsvarande en
AC plugg, därmed namn som plug type, wall plug-in , plug in eller
plugtop adapter.
Adapteren monteras i vägguttaget och