ICT / ITE / Medical Power Supply

GTM962254PWWWVVX-XF
GTM962254PWWWVVX-XF, ICT / ITE / Medical Power Supply,  60601-1-4th Ed. , Open Frame/ L Frame/Cage/ Potted Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140W, 12-54V in 0.1V increments, Approvals: CB 60601-1 (pending); CE; China RoHS; UKCA; Morocco; EAC; WEEE; VCCI; Ukraine; Level VI; RoHS; cRUus (pending);GTM962254PWWWVVX-XF, ICT / ITE / Medical Power Supply, 60601-1-4th Ed. , Open Frame/ L Frame/Cage/ Potted Internal, Regulated Switchmode AC-DC Power Supply AC Adaptor, Forced airflow for full rated power (CFM): 10CFM, Input Rating: 100-240V~, 50-60 Hz, , Output Rating: 225 Watts, Power rating with convection cooling (W) 140W, 12-54V in 0.1V increments, Approvals: CB 60601-1 (pending); CE; China RoHS; UKCA; Morocco; EAC; WEEE; VCCI; Ukraine; Level VI; RoHS; cRUus (pending);
Information
Model NumberGTM962254PWWWVVX-XF
Agency Documentshttp://www.globtek.info/certs/GTM96225xP%20/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000MljATEAZ
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000MljATEAZ
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000MljATEAZ
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000MljATEAZ
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O3a00000MljATEAZ
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O3a00000MljATEAZ
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeOpen Frame/ L Frame/Cage/ Potted Internal
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT / ITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)3A
Max Output Power Rating (W)225
Output Voltage Range (V)12-54
Auxiliary/Fan Output Voltage (V)
Auxiliary/Fan Output Power (W)
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionN/A
Size (mm)101.6 (L) x 50.8 (W) x 31.0 (H)
EnclosureUser-added image


 
3D File Downloadhttps://www.globtek.com/dl/GTM962250PWWWVVX-XF.igs
Rating Table
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM962254P13024B-EF*245120
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 85-264VAC, Nameplate: 100-240VAC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Input Current:2.75A typ. @ 85VAC, 1.0A typ. @ 230VAC (full load)
No Load Input Power:< 500mW
Inrush Current:< 75A @ 230VAC (cold start @ 25°C)
Efficiency:90 - 95% typ. (full load)
Power Factor:>0.90 @ 115VAC, >0.85 @ 230VAC, full load

Output

Turn-on Delay:< 1 second @ 85VAC
Line Regulation:± 0.5% (measured at connector)
Startup Overshoot:< 5% (full load)
Transient Response:< 5% deviation (with 25% load step), recovery to within 1% in 1ms
Hold-Up Time:10ms min. (full load)
Output Indicator:Green LED

Main Output

Output Power:120W
Output Regulation:± 1.0% (measured at connector)
Ripple:< 1% pk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)

Auxiliary Output

Output Power:10W
Output Regulation:- 1.0% / + 5% (measured at connector)
Ripple:< 100mVpk-pk (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW)

Protections

Input Protection:MOV transient suppressor, dual fuses (line + neutral)
Over-Voltage Protection:110-130% of main output. Latched-off, cycle AC to reset
Over-Current Protection:Main output: 140% typical, auto-recovery
Auxiliary output: 110 - 215%, auto-recovery
Short Circuit Protection:Non-latched with auto-recovery
Over-Temperature Protection:NTC temperature sensor embedded in transformer, trip between 115 - 120°, latched-off, cycle AC to reset (auto-recovery available as special option)

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-20°C to 50°C (full output power), -25°C to 80°C (derated)
Storage Temperature:-30°C to 85°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m max.
Vibration:Conforms to EN60068-2-6, ISO80601-2, EN1789

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth
Intended Medical Application:Type-B or Type-BF
Touch Current:3-conductor input - NC: <25µA, SFC: <200µA
2-conductor input - NC: <65µA, SFC: <140µA
Earth Leakage Current3-conductor input: <200µA
2-conductor input: N/A
Means of Protection:2 x MOPP
Primary-Secondary Bridging Capacitance:Two IEC60384-14 certified Y1 capacitors in series

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN 55011, EN61000-6-3, EN61000-6-4, CISPR11/CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 20KV air discharge (applied to input or output terminals)
Radiated RF Immunity:EN61000-4-3, 20V/m 80-2700MHz, 80% 1KHz AM, 80% 5Hz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, (6VRMS in ISM/amateur bands), 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 30A/m
Voltage Dip Immunity:EN61000-4-11
 

Special Options

  • Custom labels/markings
  • Short term output surge capability
  • Reduced touch current
  • Reduced output ripple
  • Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
  • IEC61000-3-2 Class-C line harmonics for LED lighting applications
  • Non-latching (auto-recover) over-temperature protection
  • Potentiometer to adjust/trim output voltage
Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Cellular Packag
Individual Box/Gift Box Color
Master Carton Size (mm)450 x 461 x 182
Gross Weight (kg)8.68
Label Width (mm)TBD
Label Height (mm)TBD
Input Configuration
DescriptionUser-added image
Optional Input Wiring Kits are available:
PN/Ordering NoLengthEnd AEnd B
C810070M6VAR2(R)60IEC 60320 C8JST VAR-2
C1410070M6VAR2(R)60IEC 60320 C13JST VAR-2
VAR2210070M7VAR2(R)73JST VAR-2JST VAR-2
Custom lengths, construction, cable types, ferrites, filters, and termination available upon request.
Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php

No Logo Applicable

CB for IEC 60601-1:2005 (Third Edition) + CORR. 1 (2006) + CORR. 2 (2007) + AM1 (2012) or IEC 60601-1 (2012 reprint) (Ed 3.1) up to 48V only (pending)
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
User-added image
 
UKCA Certification
User-added imageIndoor Use Only - Mark is on the label or Molded in the case

User-added image  
CE Certification
User-added imageAttention Mark / Refer to operating manual for operating and service instructions
User-added imagecRUus UL Recognized Component E341350 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1:14 (2008) (pending)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
User-added image  Certification # TC RU AR46.B.75423 Custom Union of Russia, Belarus and Kazakhstan
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
188876724.0; 5.05.00; 2.00
173596824.05.00
Vad är ett IEC 60601-1-1-11 hemmamedicinsk power supply ?

FDA definerar medicinske produkter vid användning hemma för användare av ej-kliniske- eller kortvarige omgivningar, som är produserad helt eller delvis av användare krävs för tillräckligt etikettinformation för användare, och vill i vanliga fall kräva träning för användare av vårdpersonal för att bli använd effektivt och säkerhetsmessig. Detta inkluderar permanent och tillfällig inskärpda anordningar och ett produkt som en person måste använda för att ta igjen sig och rehabilitera sig. Ett IEC 60601-1-1-11 medicinsk godkänd power supply, är en AC/DC omvandlare som möter standarder specifiserade i IEC 60601-1-1-11. Bortsett från basiskrav för medicinska power som högt dielektriskt med fast spänning och low leakage ström, måste dessa medicinska power ochså möta krav till Class II och minimum IP 21. IEC 60601-1-1-11 är ochsa listad i produktets CB, UL och andra bestämda godkännanderapporter.

Hur kan jag känna till att jag behöver ett IEC 60601-1-11 godkänd AC adapter ?

Vad är ett IEC 60601-1 medicinsk godkänd power supply AC adapter ?

IEC 60601-1-2 medicinsk godkänd power supply omvandlar spänning från vegguttaget till lägre spänning, typisk DC som användes för att ge ström till ett medicinsk apparat. IEC 60601-1-2 medicinska power är inkapslade i ett plasthus och är tillgängliga med båda 2 och 3 pins inngång. Dessa är ochså tillgängliga som open frame för att användas monterade i ett medicinsk apparat. Dessa AC/DC omvandlare är designad i överensstämmelse med internationala medicinske standarder och är i överensstämmelse med bestämda aspekt av dom som avvikar från generisk information - och kommunationtekniska power.

Varför är mitt IEC 60601-1 power supply sertificerad till IEC 60601-1-3 när sista standard är IEC 60601-1-4 ?

Ett IEC 60601-1-2 medicinsk godkänd power supply AC adapter omvandlar inngångsspänning till en lägre spänning, typisk DC, som ger ström till ett medicinsk apparat. IEC 60601-1-2 medicinsk godkända power supply är typisk kapslade i ett plasthus och kan levereras med 2 eller 3 pins inngångskontakter. Dom åar ochsåtillgängliga som open frame för montering inuti ett medicinsk apparat. Dessa AC/DC omvandlare är godkända enligt internationala medicinska standarder och är i överensstämmelse med generisk information- och kommunikationsteknologi strömförsörjare.
Varför är mitt IEC 60601-1 power supply sertificerad till IEC 60601-1-3 när sista standard är IEC 60601-1-4 ?

IEC 60601-1 har olika sektioner för säkerhetsspesifikationer och EMC/EMI. Den sista revision av säkerhet för IEC 60601-1 är 3. version, och för EMI/EMC är den siste revision 60601-1-2 4. version.

Vad är skillnaden mellan IEC 60950-1 och 60601-1 medicinsk godkänd power supply ?

IEC 60950-1 och IEC 60601-1-2 power supply är båda AC/DC omvandlare och vill vara antigen interna eller externa, men är båda designad för olika specifikationer för att anpassa slutproduktet. Medan basis spec. är samma, som input och output spänning och mekaniska spesifikationer , är det ochså många olikheter. Någon av dom viktigaste skillnader är at medicinsk IEC 60601 godkända AC/DC adaptrar kan motstå en högre dielektrisk spänning och måste ha lägre läckage ström. Det är många andra skillnader och ochså hänsyn att ta hand om beroende av slutproduktet.

När blev 60601-1-2, 4. upplaga satt i gång ?

60601-1-2, 4. upplaga, blev satt i gång 31 december -2018. Vad är ett IEC 62368-1 : 2018 power supply ? IEC 62368-1 : 2018 användas till säkerhet för elektriska och elektroniska apparater angående audio, video, information och kommunikationsteknologi, business- och kontormaskiner med en graderad spänning som ej överstiger 600V. Detta är en produktsäkerhetsstandard som klassifiserar energikällor, föreskrivna skydd mot dessa energikällor och ger information vid användning av- och krav till dessa skydd. Föreskrivna skyddskrav är menade för att minska sannolikhet för smärta, injurier och i fall av brand och egendom skador. Et IEC 62368 godkänd AC/DC power supply, är ett adapter som är testad och auktoriserad enligt bestämda standard. Ersätter ett IEC 62369-1 godkänd power supply ett IEC 60950-1 godkänd power supply ? 20 december 2020 är säkerhets- standardene IEC 60950-1 och IEC 60065 historia och ersättes av IEC 62368-1angående tekniska - och audio video produkter. I nord-Amerika vill ETL och UL 60950-1 godkanningar fortfarande existera och vill antagligen användas ytterligare. Vad är Level VI effektivitet ? Nummer I till VI är en international effektmärkeprotokoll som tillåter producenter att designa effektivitetsnivået av ett produkt. Detta är baserad på mätningar av energieffektiviteten och konsumtion vid no load av externa AC/DC adaptrar eller power supply som testas vid olika lastnivåer. No Load konsumptionen refererar till konsumption som ett externt power supply konsumerar även om produktet som önskas strömförsörjad är avstängd eller koplat av. Är Level VI ett krav ? Level VI effektivitet är obligatorisk i många länder och regioner för särskilda produkter och applikationer. Vad är ECO Design Directive 2009/125/EC ? ECO . Design Direktivet är lagstadgad i Europa i dom senaste energikrav för bevarande av AC/DC adaptrar och externa power. What is the The Unique Device Identification (UDI) for my GlobTek medical grade power supply?

The Unique Device Identification (UDI) as required by the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) is required for registered medical devices. While GlobTek medical grade power supplies carry full medical certifications they're actually not considered medical devices themselves but a component of such. And therefore do not have registration with the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) and therefore so not carry a The Unique Device Identification (UDI). Hur fungerar ett AC/DC adapter ? AC/DC adapteren eller exsternt power supply är bestående av ett power supply som är skyddad i ett plasthus motsvarande en AC plugg, därmed namn som plug type, wall plug-in , plug in eller plugtop adapter. Adapteren monteras i vägguttaget och
Begär information
Call
Email
💬
Text
💁
Chat
?
Begär en offert
Kan vi hjälpa dig?
Kan vi hjälpa dig?