GTM961200P120VV.V-TP(SR with fixed Plug 2 pin), ICT/ITE Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, See "Blade/Cord Installed" section.
Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths., Output Rating: 120 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: CB 62368; Morocco; PSE; VCCI; PSE; PSE; CE; WEEE; Ukraine; RoHS; Level VI; China RoHS; cETLus; cETLus 60601-1-11; EAC; S-Mark 62368; GTM961200P120VV.V-TP(SR with fixed Plug 2 pin), ICT/ITE Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, See "Blade/Cord Installed" section.
Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths., Output Rating: 120 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: CB 62368; Morocco; PSE; VCCI; PSE; PSE; CE; WEEE; Ukraine; RoHS; Level VI; China RoHS; cETLus; cETLus 60601-1-11; EAC; S-Mark 62368;
Model Number (Final ordering #/Part No to be defined)
Voltage
Amps (A)
Watts (W)
RFQ
* (Final ordering #/Part No to be defined)
Specifications
Input
Input Voltage:
Specified: 90-264VAC, Nameplate: 100-240VAC 100% rated load current for 90-264VAC 90% rated load current for 85-264VAC 100% rated load current for 90-370VDC
Input Frequency:
Specified: 47-63Hz, Nameplate: 50-60Hz
Power Factor:
0.90 min. @ 230VAC, 0.97 min. @ 115VAC
No Load Input Power:
< 150mW @ 115/230VAC
Inrush Current:
< 65A @ 115VAC, < 130A @ 230VAC (cold start)
Efficiency:
DoE Level VI and EU CoC Tier 2 compliant
Output
Turn-on Delay:
1 second typ.
Output Regulation:
± 4% (measured at output connector)
Line Regulation:
± 0.5% typ. (measured at output connector, full load)
Ripple:
1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Startup Overshoot:
5% max.
Transient Response:
5% max. deviation, 1ms typ. recovery time (with 25% to 50% load step)
Hold-up Time:
20ms min.
Power Indicator:
Green LED
Switching Frequency:
Variable, 25KHz - 125KHz, depending on load
Protections
Input Protection:
300VAC MOV transient suppressor, input line fusing
Over-Current Protection
Current limited to less than < 170W / Vout(nom.) and < 13A, auto-restart
Short-Circuit Protection:
Auto-restart
Over-Voltage Protection:
110 - 135% (60V max for models rated 45 - 54V), full load condition, latched off, cycle AC to reset
Over-Temperature Protection
Internal ambient NTC temperature sensor, latched off, cycle AC to reset
Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:
Regarding operating temperature a. See below de-rating table for output power capability at alternate temperature b. Extended low-end temperature range available as a custom option
Safety
Dielectric Withstand Voltage:
4000VAC or 5656VDC from input to output 3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:
Class I: 20µA max. Class II: 70µA max.
Earth Leakage Current
Class I: 300µA max. Class II: N/A
Means of Protection:
2 x MOPP
Output Isolation Options:
Class I: C6 or C14 inlet (output negative tied to Earth contact) Class II: C8 or C18 inlet Class II FE: C6 or C14 inlet (output isolated from Earth contact) Review isolation options by reading our white paper PSU Isolation and Identity.
Primary-to-Secondary Bridging Capacitors:
Two IEC60384-14 Class Y1 capacitors
Earth Continuity Test:
< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:
See listing at end of this datasheet for specific standards
Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:
Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:
EN61000-3-2, Class A
Voltage Fluctuations/Flicker:
EN61000-3-3
Electrostatic Discharge (ESD) Immunity:
EN61000-4-2, 10KV contact discharge, 18KV air discharge
Radiated RF Immunity:
EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:
EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:
EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:
EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:
EN61000-4-8, 3A/m
Voltage Dip Immunity:
EN61000-4-11
Enclosure
Housing:
High impact plastic, 94V0 polycarbonate, non-vented
Size:
149.4 * 62.6 * 33.5mm, ± 1.0mm
AC Input Mechanical Options:
C6, C8, C14, or C18 IEC inlet
Markings:
Label and/or pad printed and/or laser-etched into case
Special Options
Reduced leakage current to meet IEC60601-1 Type-CF limits
Improved EN61000-4-5 line surge immunity (3KV differential, 5KV common-mode)
Reduced harmonic current levels for LED lighting (EN61000-3-2 Class C) for 85 - 120W load
Short term output surge capability for motors or other high peak current loads
Ruggedized construction with improved shock and vibration resistance
Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
Custom cordsets, special cordage and connector types
Custom housing markings
Custom housing/cordage colors
Tightened output voltage tolerance
Reduced output ripple level
Reduced output power rating
Low temperature option, down to -40°C
Epoxy potted version "P2" or "P3" suffix, with flying wires or custom cables
"Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
Improved ingress protection (IP) rating
Output Connectors
Several output connector options are available with various output current ratings. GlobTek can supply 10A rated 2.1mm and 2.5mm style DC Power Jacks, to complement our 10A output rated 2.1mm and 2.5mm DC power plugs used on our output cordsets.
See "Blade/Cord Installed" section.
Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths.
Output Configuration
Common output connector options: Click to add to your request.
Contact GlobTek for your specific requirements or custom solutions.
Approvals
Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.
Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.
Logo
Description
Medical 4th Ed.
EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
No Logo Applicable
CB for IEC 62368-1:2014 (Second Edition)
Test standard:
EN 55032: 2012+AC: 2013
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 55024:2010
EN 60601-1-2:2015
CHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
Indoor Use Only - Mark is on the label or Molded in the case
JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
JAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
JAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
RoHS
Specifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
Japan: Voluntary Control Council for Interference (VCCI)
WEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm)
Mark is on the label or Molded in the case
Popular Products (Stock items)
SKU
Volts Out
Current Out (Amps)
Connector
RFQ
Sample Request
1636559
0.0
0.0
Vad är ett externt AC/DC adapter ?
externa desktop AC/DC adaptrar är ochså känd som AC adaptrar
eller AC/DC omvandlare och är en typ av externa strömförsörjningar.
Vissa elektriska apparater kräver ström, men saknar interna
komponenter för att få fram önskad spänning och ström.
Det är här ett AC adapter användas för att omvandla AC ström till
DC spänning. Vad är ett IEC 62368-1 : 2018 power supply ?
IEC 62368-1 : 2018 användas till säkerhet för elektriska och
elektroniska apparater angående audio, video, information och
kommunikationsteknologi, business- och kontormaskiner med en
graderad spänning som ej överstiger 600V.
Detta är en produktsäkerhetsstandard som klassifiserar
energikällor, föreskrivna skydd mot dessa energikällor
och ger information vid användning av- och krav till dessa
skydd.
Föreskrivna skyddskrav är menade för att minska
sannolikhet för smärta, injurier och i fall av brand och egendom
skador.
Et IEC 62368 godkänd AC/DC power supply, är ett adapter
som är testad och auktoriserad enligt bestämda standard.
Ersätter ett IEC 62369-1 godkänd power supply ett IEC 60950-1
godkänd power supply ? 20 december 2020 är säkerhets-
standardene IEC 60950-1 och IEC 60065 historia och ersättes
av IEC 62368-1angående tekniska - och audio video produkter.
I nord-Amerika vill ETL och UL 60950-1 godkanningar
fortfarande existera och vill antagligen användas ytterligare. Vad är Level VI effektivitet ?
Nummer I till VI är en international effektmärkeprotokoll
som tillåter producenter att designa effektivitetsnivået av ett
produkt. Detta är baserad på mätningar av energieffektiviteten
och konsumtion vid no load av externa AC/DC adaptrar eller
power supply som testas vid olika lastnivåer. No Load
konsumptionen refererar till konsumption som ett externt power
supply konsumerar även om produktet som önskas strömförsörjad
är avstängd eller koplat av.
Är Level VI ett krav ?
Level VI effektivitet är obligatorisk i många länder och regioner
för särskilda produkter och applikationer.
Vad är ECO Design Directive 2009/125/EC ?
ECO . Design Direktivet är lagstadgad i Europa i dom senaste
energikrav för bevarande av AC/DC adaptrar och externa
power. Hur fungerar ett AC/DC adapter ?
AC/DC adapteren eller exsternt power supply är bestående av ett
power supply som är skyddad i ett plasthus motsvarande en
AC plugg, därmed namn som plug type, wall plug-in , plug in eller
plugtop adapter.
Adapteren monteras i vägguttaget och