Model NumberGTM96900P90VV.V-TP(SR with fixed Plug 2 pin)
DescriptionGTM96900P90VV.V-TP(SR with fixed Plug 2 pin), ICT/ITE Power Supply, 60601-1-4th Ed. , Desktop/External, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, See "Blade/Cord Installed" section. Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths., Output Rating: 90 Watts, Power rating with convection cooling (W) , 12-54V in 0.1V increments, Approvals: S-Mark 62368; IRAM; UKCA; cETLus 62368-1; Morocco; PSE; PSE; PSE; CE; China RoHS; Level VI; RoHS; Ukraine; WEEE; ETL; CB 60950; cETLus; IP42; EAC; Patent US9838207B2; VCCI; LPS 60950; CB 60601-1; CB 61347; S-Mark; CB 62368;
Agency Documentshttp://www.globtek.info/certs/GTM96900P90VV.V/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000M5xhREAR
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0O3a00000M5xhREAR
CE EC-Declaration for HouseholdContact GlobTek for more information
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000M5xhREAR
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0O3a00000M5xhREAR
UKCA-Declaration for HouseholdContact GlobTek for more information
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0O3a00000M5xhREAR
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0O3a00000M5xhREAR
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryICT/ITE Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)90
Output Voltage Range (V)12-54
EfficiencyUSA DOE Level VI / Eco-design Directive 2009/125/EC, (EU) 2019/1782
Ingress ProtectionIP42
Size (mm)149.3 x 62.8 x 34.0 +/-1.0
EnclosureUser-added image




 
Rating Table
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) RFQ
GTM96900P9024-TP* 243.7590
GTM96900P9012-TPZ* 127.590
GTM96900P9024-TPZ* 243.7590
* (Final ordering #/Part No to be defined)
Specifications

Input

Input Voltage:Specified: 90-264VAC, Nameplate: 100-240VAC
     100% rated load current for 90-264VAC
       90% rated load current for 85-264VAC
     100% rated load current for 90-370VDC
Input Frequency:Specified: 47-63Hz, Nameplate: 50-60Hz
Power Factor:0.90 min. @ 230VAC, 0.97 min. @ 115VAC
No Load Input Power:< 150mW @ 115/230VAC
Inrush Current:< 65A @ 115VAC, < 130A @ 230VAC (cold start)
Efficiency:DoE Level VI and EU CoC Tier 2 compliant

Output

Turn-on Delay:1 second typ.
Output Regulation:± 4% (measured at output connector)
Line Regulation:± 0.5% typ. (measured at output connector, full load)
Ripple:1% or 200mV, whichever is greater (using a 47µF low-ESR cap + 0.1µF ceramic capacitor, measured @ 20MHz BW, at output connector)
Startup Overshoot:5% max.
Transient Response:5% max. deviation, 1ms typ. recovery time (with 25% to 50% load step)
Hold-up Time:20ms min.
Power Indicator:Green LED
Switching Frequency:Variable, 25KHz - 125KHz, depending on load
Output Type:Z-suffix only: IEC62368-1 Limited Power Source (LPS), 8A and 100W max.

Protections

Input Protection:300VAC MOV transient suppressor, input line fusing
Over-Current Protection (Non-LPS Version):110 - 160% of rated output current, auto-restart
Over-Current Protection:
(LPS "Z" Version)
Overload limited to less than 8A and less than 100W, auto-restart
Short-Circuit Protection:Auto-restart
Over-Voltage Protection:110 - 135% (60V max for models rated 45 - 54V), full load condition, latched off, cycle AC to reset
Over-Temperature ProtectionOn-chip temperature sensor (integrated in primary-side switching controller), shut down at Tj = ~150°C, restart at Tj = ~140°C

Environmental

MTBF:1,500,000 hours @ 25°C ambient, full load (Telcordia SR-332, Issue 3)
Operating Temperature:-10°C to 40°C (full load)
Storage Temperature:-30°C to 80°C
Humidity:0% to 95% relative humidity, non-condensing
Altitude:5000m
Cooling:Convection
RoHS:Complies with EU 2011/65/EU and China SJ/T 11363-2006
Note 1:Regarding operating temperature
a. See below de-rating table for output power capability at alternate temperature
b. Extended low-end temperature range available as a custom option

Safety

Dielectric Withstand Voltage:4000VAC or 5656VDC from input to output
3000VAC or 4242VDC from input to earth (Class I models only)
Touch Current:Class I: 20µA max.
Class II: 70µA max.
Earth Leakage CurrentClass I: 300µA max.
Class II: N/A
Means of Protection:2 x MOPP
Output Isolation Options:Class I: C6 or C14 inlet (output negative tied to Earth contact)
Class II: C8 or C18 inlet
Class II FE: C6 or C14 inlet (output isolated from Earth contact)
Review isolation options by reading our white paper PSU Isolation and Identity.
Primary-to-Secondary Bridging Capacitors:Two IEC60384-14 Class Y1 capacitors
Earth Continuity Test:< 0.1Ω between earth pin (on AC inlet) and PCB termination point (Class I models only)
Compliant Standards:See listing at end of this datasheet for specific standards

EMC

Applicable Standards:Medical: EN60601-1-2, 4th edition
Emissions: EN55032, EN61000-6-3, EN61000-6-4, CISPR11, CISPR22
Immunity: EN55024, EN61000-6-1, EN61000-6-2
Conducted Emissions:Class B, FCC Part 15, Class B (with resistive load)
Radiated Emissions:Class B, FCC Part 15, Class B (with resistive load)
Harmonic Current Voltage Distortion:EN61000-3-2, Class A
Voltage Fluctuations/Flicker:EN61000-3-3
Electrostatic Discharge (ESD) Immunity:EN61000-4-2, 10KV contact discharge, 18KV air discharge
Radiated RF Immunity:EN61000-4-3, 10V/m 80-1000MHz,  3V/m 1-2.7GHz, 80% 1KHz AM
EFT/Burst Immunity:EN61000-4-4, 4KV/100kHz.
Line Surge Immunity:EN61000-4-5, 2KV differential, 4KV common-mode
Conducted RF Immunity:EN61000-4-6, 3VRMS, 80% 1KHz AM
Power Frequency Magnetic Field Immunity:EN61000-4-8, 3A/m
Voltage Dip Immunity:EN61000-4-11

Enclosure

Housing:High impact plastic, 94V0 polycarbonate, non-vented
Size:149.4 * 62.6 * 33.5mm, ± 1.0mm
AC Input Mechanical Options:C6, C8, C14, or C18 IEC inlet
Markings:Label and/or pad printed and/or laser-etched into case

Special Options

  1. IEC62368-1 Limited Power Source (LPS) version (add Z suffix)
  2. Reduced leakage current to meet IEC60601-1 Type-CF limits
  3. Improved EN61000-4-5 line surge immunity (3KV differential, 5KV common-mode)
  4. Reduced harmonic current levels for LED lighting (EN61000-3-2 Class C), available in three load ranges: 27-50W, 40-65W, and 57-90W
  5. Ruggedized construction with improved shock and vibration resistance
  6. Compliance to IPC-600, IPC-610, IPC-6012 Class 2 or 3
  7. Short term output surge capability for motors or other high peak current loads (non-LPS version only)
  8. Custom cordsets, special cordage and connector types
  9. Custom housing markings
  10. Custom housing/cordage colors
  11. Tightened output voltage tolerance
  12. Reduced output ripple level
  13. Reduced output power rating
  14. Low temperature option, down to -40°C
  15. Epoxy potted version "P2" or "P3" suffix, with flying wires or custom cables
  16.  "Back EMF" upgrade, for motor loads and other high inductance applications with reverse energy flow requirements
  17. Improved ingress protection (IP) rating

Output Connectors

 

 

Derating CurveUser-added image
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)158*78*65
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)490 x 410 x 300
Gross Weight (kg)15.2
Label Width (mm)79.5
Label Height (mm)39.5
Input Configuration
DescriptionSee "Blade/Cord Installed" section. Contact GlobTek for customization requests such as Molded country plugs, Molex or TE connectors, or IEC connectors mounted on any type of cable in any customer specified lengths.
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)

No Logo Applicable

CB for IEC 60601-1:2006/A1:2013+A12:2014 IEC 60601-1-11:2015

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC61347-1:2015 + A1:2017 IEC61347-2-13:2014, A1:2016

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added image  Test standard: EN 55032: 2012+AC: 2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added image  Declaration ДС № ЕАЭС N RU Д-US.КА01.В.10453_19 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision: 01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014]
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP42Ingress Protection: ?IP42 to IEC60529:2001 Protection against granular foreign bodies - Protected against direct sprays up to 15o from the vertical Optional
User-added image
PRECAUCION: PARA USO EN EQUIPOS ELECTRONICOS SOLAMENTE
 
IRAM certificateDC-E-G71-005.1 to IEC 62368-1:2014
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC15?30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50469658, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30?60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source if Z suffix on model number
User-added image
 
Morocco SDoC declaration http://www.globtek.info/certs/Morocco%20SDoC%20Declaration/
Patent pendingPatent pending
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
S-Mark Certificate EN 60601-1:2006 + A1:2013 + A12:2014 EN 60601-1-11:2015 (http://www.intertek.com/marks/s/)
User-added image
 
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
User-added image
Serial Number Information
User-added imageUKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
Vad är ett externt AC/DC adapter ? externa desktop AC/DC adaptrar är ochså känd som AC adaptrar eller AC/DC omvandlare och är en typ av externa strömförsörjningar. Vissa elektriska apparater kräver ström, men saknar interna komponenter för att få fram önskad spänning och ström. Det är här ett AC adapter användas för att omvandla AC ström till DC spänning. Vad är ett IEC 62368-1 : 2018 power supply ? IEC 62368-1 : 2018 användas till säkerhet för elektriska och elektroniska apparater angående audio, video, information och kommunikationsteknologi, business- och kontormaskiner med en graderad spänning som ej överstiger 600V. Detta är en produktsäkerhetsstandard som klassifiserar energikällor, föreskrivna skydd mot dessa energikällor och ger information vid användning av- och krav till dessa skydd. Föreskrivna skyddskrav är menade för att minska sannolikhet för smärta, injurier och i fall av brand och egendom skador. Et IEC 62368 godkänd AC/DC power supply, är ett adapter som är testad och auktoriserad enligt bestämda standard. Ersätter ett IEC 62369-1 godkänd power supply ett IEC 60950-1 godkänd power supply ? 20 december 2020 är säkerhets- standardene IEC 60950-1 och IEC 60065 historia och ersättes av IEC 62368-1angående tekniska - och audio video produkter. I nord-Amerika vill ETL och UL 60950-1 godkanningar fortfarande existera och vill antagligen användas ytterligare. Vad är Level VI effektivitet ? Nummer I till VI är en international effektmärkeprotokoll som tillåter producenter att designa effektivitetsnivået av ett produkt. Detta är baserad på mätningar av energieffektiviteten och konsumtion vid no load av externa AC/DC adaptrar eller power supply som testas vid olika lastnivåer. No Load konsumptionen refererar till konsumption som ett externt power supply konsumerar även om produktet som önskas strömförsörjad är avstängd eller koplat av. Är Level VI ett krav ? Level VI effektivitet är obligatorisk i många länder och regioner för särskilda produkter och applikationer. Vad är ECO Design Directive 2009/125/EC ? ECO . Design Direktivet är lagstadgad i Europa i dom senaste energikrav för bevarande av AC/DC adaptrar och externa power. Hur fungerar ett AC/DC adapter ? AC/DC adapteren eller exsternt power supply är bestående av ett power supply som är skyddad i ett plasthus motsvarande en AC plugg, därmed namn som plug type, wall plug-in , plug in eller plugtop adapter. Adapteren monteras i vägguttaget och
Begär information

Model

Call
Email
💬
Text
💁
Chat
?
Begär en offert
Kan vi hjälpa dig?
Kan vi hjälpa dig?