The 90W Desktop Power Supply family also serves as an LED Driver which meets 61000-3-2 Class C Harmonics and has IEC61347, LPS, and UL1310 (Class 2 Transformer) certification, Class II. GTM96900P90VV.V-T2
90W Desktop Power Supply Adapter offering IEC60950, 60601, 62368, UL1310, IEC60335 Certifications and DOE EPS 2.0 Level VI compliant, Class II
Information
Model NumberGTM96900P90VV.V-T2
DescriptionThe 90W Desktop Power Supply family also serves as an LED Driver which meets 61000-3-2 Class C Harmonics and has IEC61347, LPS, and UL1310 (Class 2 Transformer) certification, Class II.
Agency Documentshttp://www.globtek.info/certs/GTM96900P90VV.V/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MigSZEAZ
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000MigSZEAZ
CE EC-Declaration for HouseholdContact GlobTek for more information
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000MigSZEAZ
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeDesktop/External
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryITE / Medical Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)90
Output Voltage Range (V)12-54
EfficiencyVI
Ingress ProtectionIP41
Size (mm)149.38 x 62.6 x 33.5 +/-1.0
EnclosureUser-added image
Rating Table
Preferred ratings shown below.
Custom output voltages available in 0.1V increment from the minimum voltage listed to the maximum voltage listed; contact sales.
Model Number (Final ordering #/Part No to be defined) VoltageAmps (A)Watts (W) LPS RFQ
GTM96900P8512-T2* 127.185.2 N
GTM96900P9015-T2* 15690 N
GTM96900P9019-T2* 194.7389.87 N
GTM96900P9024-T2* 243.7590 N
GTM96900P9030-T2* 30390 N
GTM96900P9036-T2* 362.590 N
GTM96900P9048-T2* 481.87590 N
GTM96900P9054-T2* 541.6689.64 N
GTM96900P8512-T2Z* 127.185.2 Y
GTM96900P9015-T2Z* 15690 Y
GTM96900P9019-T2Z* 194.7389.87 Y
GTM96900P9024-T2Z* 243.7590 Y
GTM96900P9030-T2Z* 30390 Y
GTM96900P9036-T2Z* 362.590 Y
GTM96900P9048-T2Z* 481.87590 Y
GTM96900P9054-T2Z* 541.6689.64 Y
GTM96900P90VV.V-T2-XXXXCUSTOM CUSTOMCUSTOM CUSTOM
* (Final ordering #/Part No to be defined)
SpecificationsA) ELECTRICAL SPECIFICATIONS:
01. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
         90-264Vac range @ 100% of rated load current
         85-264 Vac range @ 90% of rated load current
         90-370 VDC range @ 100% of rated load current
02. Input Frequency: Specified 47-63 Hz, Nameplate rated 50/60Hz
03. Power Factor: 0.90 minimum @ 230Vac, 0.97 minimum @ 115Vac
04. Output Type: LPS (Limited Power Source), limited to less than 8A and 100W
04. Output Regulation: +/- 4% measured at the output connector
05. Line Voltage Regulation: +/- 0.5% typical measured at full load
06. Green Power On Indicator LED
07. Output Ripple (Vp-p): 1% or 200 mV whichever is greater, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with a low impedance 47 uf electrolytic capacitor connected at the end of the output connector at nominal line
08. Turn-ON/OFF Overshoot: 5% maximum, 1 mS typical recovery time for 25% to 50% step load
09. Turn-ON Delay: 1 second typical
10. Hold-Up Time: 20 mS minimum
11. Inrush Current: 30A maximum at 115Vac input and 60A maximum at 230 Vac input
12. Switching Frequency: Varies from 25KHz to 125KHz
13. Efficiency: Compliant with Efficiency Level VI Standard and 230 CoC Tier 2 Limits
14. No Load Standby Power: <0.15 W @ 230Vac

B) PROTECTION
01. Input Protection: Input line fusing and 300Vac rated MOV
02. Non-LPS version:  Current Limited to 110% to 160% of rated output current
03. LPS version:  Short Circuit/Overload  limited to less than 8A and 100W (add Z suffix in model #)
04. Over-Temperature : Inherently protected against continuous overload at high temperature
05. Output Over-Voltage: 110% to 135% of nominal output voltage under full load condition, and less than 60V max. Latching protection, cycle AC OFF to reset.

C) SAFETY
01. Dielectric Withstand Voltage: 4000Vac or 5656Vdc from input to output,
On Class I models, 3000Vac or 4242Vdc from input to earth
02. Earth Leakage Current: Class I models < 300uA, N/A for Class II models
03. Touch Current: Class I models < 20uA, Class II models < 70uA
04. Output Isolation Options:
   a) C8 or C18 Inlet, Class II
   b) C6 or C14 Inlet, Class II FE, Output Isolated from Earth contact
   c) C6 or C14 Inlet,  Class I, Output negative directly attached to Earth contact
05. Earth Continuity Test: < 0.1 Ohm between Earth Pin at AC input and PCB termination point (Class I models only)
06. Means of Protection: 2 x MOPP
07. Primary to Secondary Bridging Capacitance: Two IEC60384-14 certified Y1 type capacitors in series
08. Compliant Standards: See listings at end of this drawing for specifics

D) EMC
EN 60601-1-2, 4th edition
Emissions, per EN 55032, EN 61000-6-3, EN 61000-6-4
  Conducted Emissions: Class B, FCC Part 15, Class B
  Radiated Emissions: Class B, FCC Part 15, Class B
Line Frequency Harmonics EN61000-3-2, Class A
Voltage Fluctuations/Flicker EN61000-3-3
 
Immunity, per EN 55024, EN 61000-6-1, EN 61000-6-2
  Static Discharge Immunity EN61000-4-2, 10kV Contact Discharge, 18kV air discharge
  Radiated RF Immunity EN61000-4-3, 10V/m 80-1000MHz, 3V/m 1-2.7GHz, 80% 1KHz AM.
  EFT/Burst Immunity EN61000-4-4, 4kV/100kHz.
  Line Surge Immunity EN61000-4-5, 2kV differential, 4kV common-mode
  Conducted RF Immunity EN61000-4-6, 3Vrms, 80% 1KHz AM
  Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m
  Voltage Dip Immunity EN61000-4-11, Criteria

E) OTHER:
01. MTBF: 1,000,000 Hours @ 40°C ambient temperature, Full Load
02. Operating Temperature:
    GTM96900P Family: 0°C to 50°C ambient temperature with full load
    Regarding Operating Temperature, 
    a- See below derating table for output power capability at alternate temperature
    b- Extended low end temperature range available as custom option
03. Humidity: 0% to 95% relative humidity, non-condensing
04. Storage Temperature: -30°C to 80°C
05. Cooling: Convection
06. ROHS: Compliant with latest regulations, see approvals section below
07. Operational Altitude: 5000M

F) DESKTOP STYLE ENCLOSURE
01. Housing: High impact plastic, 94V0 polycarbonate, non-vented
02. Size: 149.4 x 62.6 x 33.5 +/-1.0 mm
03. Markings: Label or Laser printed
04. AC Input mechanical options: Desktop C6, C8, C14 or C18 IEC Inlet.

G) SPECIAL OPTIONS
01. LPS or non-LPS versions (Z suffix for LPS model)
02. Custom Cordsets, various cordage types, and connector types
03. Custom Markings
04. Short term Output Surge Capability, as a non-LPS version
05. Reduced Leakage Current version, medical CF leakage current compliance
06. Tightened output voltage tolerance
07. Reduced Output Ripple Level
08. Reduced output power Marking/Rating
09. LED Lighting, Class C Line Harmonics per 61000-3-2
       Three Power Ranges available: 27-50W, 40-65W and 57-90W
10. High Rel PCB laminate with Plated through Holes for IPC610 Class 2 Compliance
11. Low Temperature operation, down to -40°C
12. Special Housing Colors and Cordset Colors
13. Epoxy Potted Version, “P2” or “P3” suffix, with flying wires

H) OUTPUT CONNECTORS
Several output connector options are available with various output current ratings.
GlobTek can supply 10A rated 2.1mm and 2.5mm style DC Power Jacks, to complement our
10A output rated 2.1mm and 2.5mm DC power plugs used on our output cordsets.
Please visit https://en.globtek.com/news/high-current-coaxial-barrel-plug-jacks-for-high-wattage-power-supplies for a real time product offering of mating connectors.
 
 
Derating CurveUser-added image
Qty (ea.)/Carton20
Individual Box/Gift Box Size (mm)Egg Crate
Individual Box/Gift Box Color
Master Carton Size (mm)427 x 405 x 158
Gross Weight (kg)15.6
Label Width (mm)50.0
Label Height (mm)110.0
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connector, Class II, Non-Earth Ground (aka "Figure-8")
User-added image
Mates with IEC 60320/C7 Plug
Standard International IEC 320/C7 Cordsets
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Please contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets
4511116F703A(R)N. American, Type ANEMA 1-15PIEC 320/C718306
5014112M703A(R)AustralianAS 3112IEC 320/C720007
2094112M703(R)ArgentinaIRAM 2063IEC 320/C720007
4533501M8703(R)ChinaGB 2099.1IEC 320/C718306
2074112M703A(R)European, Type CCEE 7/16IEC 320/C720007
451J3401M8703(R)JapanJIS 8303IEC 320/C718306
6104112M703A(R)UK, Type GBS1363IEC 320/C720007
2044112M703®KoreaKS C8305IEC 320/C720007
4033401M8703A(R)TaiwanCNS690IEC 320/C718306
207B4111M8703(R)BrazilNBR14136IEC 320/C718006
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug) C Type (Coaxial 5.5x2.1mm plug) K Type (Coaxial 3.5x1.3mm plug) LL Type (5.5x2.5mm Locking 760k type) CL Type (5.5x2.1mm Locking S761k type) Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P) YL4 Type (KPPX-4P) EJ1/2/3/4/5 (EIAJ RC-5320A type connectors) MSB Type (Micro USB) Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals
LogoDescription

No Logo Applicable

CB for IEC 60601-1:2006/A1:2013+A12:2014 IEC 60601-1-11:2015

No Logo Applicable

CB for IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013

No Logo Applicable

CB for IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013

No Logo Applicable

CB for IEC 62368-1:2014 (Second Edition)
User-added imageCCC Altitude up to 5000 m GB17625.1-2012, GB4943.1-2011, GB/T9254-2008
User-added image  Test standard: EN 55032: 2012+AC: 2013 EN 61000-3-2:2014 EN 61000-3-3:2013 EN 55024:2010 EN 60601-1-2:2015
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11
Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to AAMI STD.ES60601-1,IEC 60601-1-11 Certified to CAN/CSA STD.C22.2 NO.60601-1
Conforms to UL STD. 1310
Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 1310 Certified to CSA STD. C22.2 NO.223
Conforms to UL STD. 60950-1 
Certified to CSA STD C22.2 NO.60950-1
Conforms to UL STD. 60950-1 Certified to CSA STD C22.2 NO.60950-1

 
User-added image  Declaration # ЕАЭС N RU Д-US.АД75.В.01052 Custom Union of Russia, Belarus and Kazakhstan http://www.globtek.com/redirect/?loc=gost-certificate-eac-declaration
User-added imageMedical Electrical Equipment - Part 1: General Requirements For Basic Safety And Essential Performance (R2012) [AAMI ES60601-1:2005 +C1;A2] [CSA C22.2#60601-1:2014 Ed.3] [AAMI HA60601-1-11:2015 Ed.2]
User-added imageInformation Technology Equipment Safety Part 1: General Requirements >Valid without technical revision: 01Jan2022< [UL 60950-1:2007 Ed.2 +R:14Oct2014]
User-added image
Class 2 Power Unit
Class 2 Power Units [UL 1310:2011 Ed.6 +R:12Dec2014] up to 5A Power Supplies With Extra-Low Voltage Class 2 Outputs [CSA C22.2 No.223:2015 Ed.3]
CAN ICES-3(B)/NMB-3(B)
Compliance of this PSU with Industry Canada, Class B demonstrated with a standard output load. The ICES law stipulates that system-level testing is required to demonstrate compliance with the ICES-3 emission limits with the actual system load.
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP41Ingress Protection: IP41 to IEC60529:2001 Protection against granular foreign bodies - Protected against vertically falling drops of water
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC15≤30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50313287, to J60950-1(H26) , J55022(H22),J3000(H25)[DC30≤60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image
 
Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source if Z suffix on model number
Patent pendingPatent pending
User-added imageRCM certificate SAA-170646-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm)
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
S-Mark Certificate EN 60601-1:2006 + A1:2013 + A12:2014 EN 60601-1-11:2015 (http://www.intertek.com/marks/s/)
User-added image
 
S-Mark Certificate EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+A2:2013 (http://www.intertek.com/marks/s/)
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request Distributor Stock (Click to order)
556413127.08Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
TR9KE7500LCP-IM(R6B)127.5Female Barrel 5.5 * 2.5 * 11mm with no internal Spring Clip and with Locking Notch or Equal 40
678933127.5Switchcraft S1017 or equivalent
TR9KE7500CCP-IM(R6B)127.5Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 20
571782127.08Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
572491127.08Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
358817127.5T-plug system
556521127.5Strip only 0.25" insulation from Black conductor, 0.125" insulation from white conductor
676827127.5Strip only 0.25" insulation from Black conductor, 0.125" insulation from white conductor
540428156Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
358818156T-plug system
TR9KH5000T00-IM(R6B)185T-plug system 18
TR9KZ4737T00-IM(R6B)194.73T-plug system 20
701481241.875ROJ 250 ±5mm, Strip 6 ± 2mm
767655243.75MOLEX P/N:43025-0200 Micro-fit 3.0 (2) circuit connector housing with 430300038 Female terminals or Equal, with connector overmold
221179243.75Female Barrel 5.5 * 2.5 * 10mm with internal Spring Clip and Locking Notch or Equal
TR9KI3750LCPCIM(R6B)243.75Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal 40
TR9KI3750CCP-IM(R6B)243.75Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal 37
TR9KI3750T00-IM(R6B)243.75T-plug system 20
522764243.75Female Barrel 5.5*2.1*11mm w/ Spring Clip & Locking Notch or Equal
409996243.75Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
605116241.7Female Barrel, Locking, 5.5 * 2.5 * 13.8mm w/ 4.0mm Thumb Screw or Equal (12mm barrel length to stopper)
610130242.125ROJ 250 ±5mm, Strip 6 ± 2mm
537622241.87Stripped 50 +/-5mm; Tinned 9.5 +/- 2mm or Equal
541233303Stripped 25 +/-1mm; Tinned 8 +/-1mm or Equal
TR9KR3000T00-IM(R6B)303T-plug system 19
767656332.72MOLEX P/N:43025-0200 Micro-fit 3.0 (2) circuit connector housing with 430300038 Female terminals or Equal, with connector overmold
538956361.25Stripped 50 +/-5mm; Tinned 9.5 +/- 2mm or Equal
701701361.41ROJ 250 ±5mm, Strip 6 ± 2mm
615709361.25ROJ 250 ±5mm, Strip 6 ± 2mm
617447361.8ROJ 250 ±5mm, Strip 6 ± 2mm
636038362.5Female Barrel 5.5 * 2.1 * 11mm No internal Spring Clip nor Locking Notch or Equal
613848361.38ROJ 250 ±5mm, Strip 6 ± 2mm
610136361.5ROJ 250 ±5mm, Strip 6 ± 2mm
601686362.5Female Barrel 5.5 * 2.5 * 11mm No internal Spring Clip nor Locking Notch or Equal
597731362.5MAG2C240 (2 Pin magnetic connector)
TR9KX1875T00-IM(R6B)481.875T-plug system 20
397537541.66Female Barrel 5.5 * 2.5 * 11mm with internal Spring Clip and Locking Notch or Equal
765931541.66T-plug system