GTM91120-30VV-T2, Medical/ICT/ITE/Household use Power Supply,  60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: S-Mark IEC/EN 60601-1; SIQ 61558; EAC; UKCA; Conforms to 62368-1; cUL 60950; LPS 60950; CB EN/IEC 60335-1; RoHS; Level V; CE; China RoHS; LPS 62368; PSE; WEEE; Double Insulation; VCCI; Ukraine; FCC; SIQ; Book 60601; Fuse 60335; CB 60601-1; CB 60950; IEC 60335; IEC/EN60601-1; IEC/EN60950-1; CCC; cRUus; CE; RCM; S-Mark 60950; CE; ETL; CB 60335; PSE; PSE; PSE; PSE; S-Mark 62368; 61558-1; IEC 61558-1; Fuse 60335; IP40; IP52; Ta:40°C; GTM91120-30VV-T2, Medical/ICT/ITE/Household use Power Supply,  60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: S-Mark IEC/EN 60601-1; SIQ 61558; EAC; UKCA; Conforms to 62368-1; cUL 60950; LPS 60950; CB EN/IEC 60335-1; RoHS; Level V; CE; China RoHS; LPS 62368; PSE; WEEE; Double Insulation; VCCI; Ukraine; FCC; SIQ; Book 60601; Fuse 60335; CB 60601-1; CB 60950; IEC 60335; IEC/EN60601-1; IEC/EN60950-1; CCC; cRUus; CE; RCM; S-Mark 60950; CE; ETL; CB 60335; PSE; PSE; PSE; PSE; S-Mark 62368; 61558-1; IEC 61558-1; Fuse 60335; IP40; IP52; Ta:40°C;GTM91120-30VV-T2, Medical/ICT/ITE/Household use Power Supply, 60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: S-Mark IEC/EN 60601-1; SIQ 61558; EAC; UKCA; Conforms to 62368-1; cUL 60950; LPS 60950; CB EN/IEC 60335-1; RoHS; Level V; CE; China RoHS; LPS 62368; PSE; WEEE; Double Insulation; VCCI; Ukraine; FCC; SIQ; Book 60601; Fuse 60335; CB 60601-1; CB 60950; IEC 60335; IEC/EN60601-1; IEC/EN60950-1; CCC; cRUus; CE; RCM; S-Mark 60950; CE; ETL; CB 60335; PSE; PSE; PSE; PSE; S-Mark 62368; 61558-1; IEC 61558-1; Fuse 60335; IP40; IP52; Ta:40°C; GTM91120-30VV-T2, Medical/ICT/ITE/Household use Power Supply, 60601-1-4th Ed. , Wall Plug-in+Desktop Combination, Regulated Switchmode AC-DC Power Supply AC Adaptor, , Input Rating: 100-240V~, 50-60 Hz, IEC 60320/C8 AC Inlet connector, Output Rating: 30 Watts, Power rating with convection cooling (W) , 5-48V in 0.1V increments, Approvals: S-Mark IEC/EN 60601-1; SIQ 61558; EAC; UKCA; Conforms to 62368-1; cUL 60950; LPS 60950; CB EN/IEC 60335-1; RoHS; Level V; CE; China RoHS; LPS 62368; PSE; WEEE; Double Insulation; VCCI; Ukraine; FCC; SIQ; Book 60601; Fuse 60335; CB 60601-1; CB 60950; IEC 60335; IEC/EN60601-1; IEC/EN60950-1; CCC; cRUus; CE; RCM; S-Mark 60950; CE; ETL; CB 60335; PSE; PSE; PSE; PSE; S-Mark 62368; 61558-1; IEC 61558-1; Fuse 60335; IP40; IP52; Ta:40°C;
Information
Model NumberGTM91120-30VV-T2
Agency Documentshttp://www.globtek.info/certs/GTM91120-T2%20-T3A%20-FW/
CE EC-Declaration for Medicalhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000C2VkdEAF
CE EC-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000C2VkdEAF
CE EC-Declaration for Householdhttps://globtek.secure.force.com/models/ec_declaration?id=a0Oa000000C2VkdEAF
UKCA-Declaration for Medicalhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000C2VkdEAF
UKCA-Declaration for Industrial/Commercial/ITEhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000C2VkdEAF
UKCA-Declaration for Householdhttps://globtek.secure.force.com/models/ukca_declaration?id=a0Oa000000C2VkdEAF
Morocco SDoC Declarationhttps://globtek.secure.force.com/models/Morocco_SDoC_Declaration?id=a0Oa000000C2VkdEAF
RoHS/RoHS3 Declarationhttps://www.globtek.com/pdf/rohs_cert/a0Oa000000C2VkdEAF
Prop 65 Statementhttps://en.globtek.com/prop-65-statement.pdf
REACH Declarationhttps://www.globtek.com/pdf/iso_certificates/REACH.pdf
Conflict Minerals Declarationhttps://www.globtek.com/pdf/conflict-minerals.pdf
Model Parameters
TypeWall Plug-in+Desktop Combination
TechnologyRegulated Switchmode AC-DC Power Supply AC Adaptor
CategoryMedical/ICT/ITE/Household use Power Supply
Input Voltage Range (V)100-240V~, 50-60 Hz
Max Input Current (A)1.5A
Max Output Power Rating (W)30
Output Voltage Range (V)5-48
EfficiencyV
Ingress ProtectionIP40 (cord), IP52(R-blades)
Size (mm)(L)101.77x(W)47.47x(H)36.7
Enclosure

User-added image




User-added image



            Units shipped without an installed input plug have a "desktop insert" installed.
Rating Table
Model Number (Final ordering #/Part No to be defined)VoltageAmps (A)Watts (W)RFQ
GTM91120-1007.5-2.5-T2*5210
GTM91120-2007.5-2.5-T2*5420
GTM91120-3007.5-1.5-T2*63.7522.5
GTM91120-3007.5-T2*7.5322.5
GTM91120-2510.5-1.5-T2*92.825.2
GTM91120-3010.5-1.5-T2*92.7724.93
GTM91120-3010.5-1.4-T2*9.13.330.03
GTM91120-3010.5-1.2-T2*9.33.229.76
GTM91120-2510.5-0.9-T2*9.62.624.96
GTM91120-1214.5-2.5-T2*12112
GTM91120-3014.5-2.5-T2*122.530
GTM91120-1714.5-1.5-T2*131.316.9
GTM91120-3019.5-4.5-T2*15230
GTM91120-3019.5-1.5-T2*181.6629.88
GTM91120-3019.5-0.5-T2*191.5729.83
GTM91120-3024-T2*241.2530
GTM91120-2736-9.0-T2*27127
GTM91120-3036-6.0-T2*30130
GTM91120-3036-T2*360.8329.88
GTM91120-3048-T2*480.62530
* (Final ordering #/Part No to be defined)
Specifications
A) ELECTRICAL SPECIFICATIONS:
1. Input Voltage: Specified 90-264 Vac, Nameplate rated: 100-240Vac
2. Input Frequency: Specified 47-63 Hz, Nameplate rated 50-60Hz
3. Output Regulation: +/- 5% measured at the output connector
4. Line Voltage Regulation: +/- 2% typical measured at full load
5. Output Ripple (Vp-p): +/-2% maximum, measured at 20 MHz bandwidth with 0.1 uf ceramic capacitor in parallel with 10 uf electrolytic capacitor connected at the end of the output connector
Optional low ripple option available (RFP4579)
6. Turn-ON/OFF Overshoot: 5% maximum, 500uS typical recovery time for 25% to 50% step load
7. Turn-ON Delay: 3 Seconds, maximum @ full load, nominal line
8. Hold-Up Time: 8 mS typical @ nominal input voltage and full load
9. Inrush Current: 60A maximum cold start @ 240Vac input
10. Switching Frequency: 100 KHz typical

B) PROTECTION
1. Over-Voltage: Protected with a Zener diode clamp across the output
2. Short Circuit: Hiccup with auto recovery
3. Over-load: Hiccup with auto recovery
4. Input Protection: Input line and neutral fusing

C) SAFETY
1. Dielectric Withstand Voltage: 5656Vdc from primary to secondary
2. Earth Leakage Current: N/A for Class II units, there is no PE Ground pin, so Earth Leakage current is not measured
3. Touch Current: Maximum allowed values: 100uA NC(Normal condition) 500uA SFC(single fault condition)

D) OTHER:
1. MTBF: 200,000 Hours @ 25°C ambient temperature
2. Operating Temperature: 0°C to 40°C ambient temperature
3. Humidity: 0% to 90% relative humidity
4. Storage Temperature: -40°C to 80°C “24h recovery time at room temperature”.
5. Cooling: Convection
6. ROHS 2: Complies with EU 2011/65/EU and China SJ/T 11363-2006

E) ENCLOSURE
1. Housing: High impact plastic, 94V0 polycarbonate, non-vented
2. Size: (L)101.73 x (W)46.47 x (H)38.2 +/-1.0 mm
3. Markings: Label and/or Pad Printed and/or Molded in the case
4. LED: Standard GREEN color to indicate power out
Derating CurveUser-added image
Qty (ea.)/Carton60
Individual Box/Gift Box Size (mm)142*62*60
Individual Box/Gift Box ColorWhite
Master Carton Size (mm)442 x 330 x 275
Gross Weight (kg)15.2
Label Width (mm)37.5
Label Height (mm)33.5
Input Configuration
DescriptionIEC 60320/C8 AC Inlet connectorBlade Insertion Instructions
R-Blade Style Instruction Video

User-added image
Mates with IEC 60320/C8 Plug

This series of Interchangeable Blade products may be used with Proprietary Interchangeable Blades as described below or with standard international power cords.
 
Optional INPUT BLADES: R-Socket: below are available blades configurations which are "not included" (unless stated above); may be purchased separately, packaged with power supply, or as a separate "R-KIT" if specified 
 
#Part NumberMain Country/RegionPlugIECEE Type
1R-NA-2(R) North America, JapanNema 1-15PType A
2R-SAA-2(R) Australia/New Zealand AS/NZ 3112 Type I
3R-UK-2(R) United Kingdom/IrelandUK, Hong Kong, Singapore, Gulf StatesType G
4R-EU-2(R)EuropeCEE 7/16Type C
5R-CN-2(R)ChinaGB 2099 Type A
6461-03030003(R)N/AR-DI(R) Desktop Insert for use with a cordN/A
7R-KIT-2(R)prepackaged kit1,2,3,4 aboveN/A
8R-KIT-2-INTL(R)prepackaged kit2,3,4 aboveN/A

User-added image

Standard Cordsets
Below are standard cordsets which are "not included" (unless stated above); these may be purchased separately or packaged with the power supply. Contact your Sales Engineer if the style required is not shown below. Many more available in different lengths, colors or cable material.

Standard International IEC 320/C7 Cordsets
  
Part NumberCountryPlugConnectorLength (mm)Length (feet)
2094112M703(R)Argentina (Type I)IRAM 2063IEC 320/C720007
5014112M703A(R)Australian (Type I)AS 3112IEC 320/C720007
207B4111M8703(R)Brazil (Type N)NBR14136IEC 320/C718006
4533501M8703(R)China (Type A)GB 2099.1IEC 320/C718306
2074112M703A(R)European (Type C)CEE 7/16IEC 320/C720007
2084111M8703(R)South Africa (Type M)BS 546IEC 320/C718006
2084111M8703B(R)India (Type D)ISI:1293IEC 320/C718006
2714111M8703A(R)India (Type C)ISI:1293IEC 320/C718006
451J3401M8703(R)Japan (Type A)JIS 8303IEC 320/C718306
2044112M703A(R)Korea (Type C)KS C8305IEC 320/C720007
4511116F703A(R)N. American (Type A)NEMA 1-15PIEC 320/C718306
4033401M8703A(R)Taiwan (Type A)CNS690IEC 320/C718306
6104112M703A(R)UK, Hong Kong, Singapore, Gulf States (Type G)BS1363IEC 320/C720007
Output Configuration
Common output connector options:
Click to add to your request.
L Type (Coaxial 5.5x2.5mm plug)
C Type (Coaxial 5.5x2.1mm plug)
K Type (Coaxial 3.5x1.3mm plug)
LL Type (5.5x2.5mm Locking 760k type)
CL Type (5.5x2.1mm Locking S761k type)
Magnetic Connector
L Type (Coaxial 5.5x2.5mm plug)C Type (Coaxial 5.5x2.1mm plug)K Type (Coaxial 3.5x1.3mm plug)LL Type (5.5x2.5mm Locking 760k type)CL Type (5.5x2.1mm Locking S761k type)Magnetic Connector
YL3 Type (KPPX-3P)
YL4 Type (KPPX-4P)
EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)
MSB Type (Micro USB)
Custom design
YL3 Type (KPPX-3P)YL4 Type (KPPX-4P)EJ1/2/3/4/5 (EIAJ RC-5320A type connectors)MSB Type (Micro USB)Inquire for custom design

For a comprehensive list of options, click here

Contact GlobTek for your specific requirements or custom solutions.

Approvals

Below follows a link to the latest regulatory certifications and marks for this specific product. National standards as well as certification schemes are constantly changing and so is the set of certification marks and symbols applicable to this product. Various standards, marks and symbols, and certificates are subject to change at any time without notice.

Additional standards or unique country certifications are available upon request. Please contact Globtek to request a quotation.

LogoDescription
Medical 4th Ed.EN/IEC 60601-1-2, 4th Edition (Please visit EMC reports for further info)
User-added imageBook 60335 up to 36 Volts
User-added image60601-1 3rd Operating Instructions
No Logo ApplicableCB report IEC 60601-1: 2005 + CORR. 1 (2006) + CORR. 2 (2007) and or EN 60601-1:2006 3rd Edition including 2MOOP requirements
No Logo CB Certificate IEC 60950-1:2005 (2nd Edition), Am 1: 2009, CB report IEC 60950-1:2005 (2nd Edition), Am 1: 2009 and EN 60950-1:2006 + Am 1:2010 + Am 11:2009 + Am 12:2011

No Logo Applicable

CB to 60335-1 5th Edition (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) CB Report/ Certificate IEC 60335-1:2010 Up to 36 volts only
 User-added imageCCC to GB4943. 1-2011; GB9254-2008; GB17625. 1-2012 with Tropical and Altitude up to 5000 m approval.

No Logo Applicable

IEC 60335-1:2010 (Fifth Edition) incl. Corr. 1:2010 and Corr. 2:2011 + A1:2013
User-added image  CE Mark: tested to comply with EN 55032:2012+AC:2013, EN 61000-3-2:2014, EN 61000-3-3:2013, EN 55024:2010, EN 60601-1-2:2015
User-added image  CE Certification CE Mark: tested to comply with EN 55032.2012+AC.2013 EN 61000-3-2.2014 EN 61000-3-3.2013 EN 60601-1-2.2015 EN 55024.2010
User-added image  CE Mark: tested to comply with EN55022:2006/A1:2007 Class B, EN610003-2, EN610003-3 including EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6N EN61000-4-11; EMI: Complies with EN55011 CLASS B and FCC Part 15B - On label or Molded in case
User-added imageAAMI ES60601-1:2005 +A1 - Medical Electrical Equipment - Part 1: General Requirements CAN/CSA-C22.2 No.60601-1:14, Third Edition Issued: 2014/03/01 - Medical Electrical Equipment - Part 1 IEC 60601-1-11 Issued: 2015/01/20 Ed. 2 Medical Elec. Equip.
User-added imageCHINA SJ/T 11364-2014, China RoHS Chart: http://en.globtek.com/globtek-rohs.php
Conforms to UL STD. 62368-1
Certified to CSA STD C22.2 NO.62368-1
Conforms to UL STD. 62368-1 Certified to CSA STD C22.2 NO.62368-1
User-added imagecRUus UL Recognized Component E172861 3rd Edition w-RM ANSI-AAMI ES60601-1 (2005 + C1:09 + A2:10) and CAN-CSA-C22.2 No. 60601-1 (2008)
User-added image
 
UL60950-1, cULus to UL 60950-1, 1st Edition, 2007-10-31 and CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07
User-added image
User-added image  Certification # TC RU AR46.B.69004 Custom Union of Russia, Belarus and Kazakhstan
User-added image
FCC PART 15 CLASS B
User-added image
 
Fuse 60335 T3.15A 250VAC Up to 36 volts
Ta:40°CIEC 61558-1 Maximum Ambient Temperature, Max 40°C
User-added image
IEC/EN60335-1 Up to 36 volts
User-added image
IEC/EN60601-1
User-added image
IEC/EN60950-1
User-added imageIndoor Use Only - Mark is on the label or Molded in the case
IP40Ingress Protection: ?IP40 to IEC60529:2001 Protection against granular foreign bodies (with I/P cord)
IP52Ingress Protection: ?IP52 to IEC60529:2001 Protected against dust - limited ingress (no harmful deposit) and Protected against direct sprays up to 15 degrees from the vertical (with R-Blades)
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50314327, to J60950-1(H26) , J55022(H22),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50473430, to J62368-1(H30) , J55032(H29),J3000(H25)[15V or less]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD50473430 , to J62368-1(H30) , J55032(H29),J3000(H25)[DC15? 30V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
User-added imageJAPAN TUV R-PSE, Cert. No. JD 50473430, to J62368-1(H30) , J55032(H29),J3000(H25)[DC30? 60V]. Please reference the following website for guidelines on PSE regulations: http://en.globtek.com/importing-ite-and-medical-power-supplies-ac-adaptors-to-japan/
 User-added image

Efficiency: complies to section 301 of Energy Independence and Security Act (EISA) complies with Energy Star tier 2 (North America), ECP tier 2 (China), MEPS tier 2 (Australia), Code of Conduct (Europe)
LPSLimited Power Source 60950
LPSLimited Power Source 62368
User-added imageJAPAN TUV Rheinland-PSE GlobTek Inc to J60950-1(H26) , J55022(H22),J3000(H25).Please follow the procedure listed in the following link for proper import to Japan: http://en.globtek.com/importing-to-japan.php.
    User-added image
SAA-161679-EA
 
RCM certificate SAA-161679-EA; Australia and New Zealand Regulatory Compliance, Mark (http://rcm.standards.org.au/rcmfaq/rcmfaq.htm
RoHSSpecifications of directive 2011/65/EU Annex VI (ROHS-2) with amendment 2015/863-EU (ROHS-3) http://www.ce-mark.com/Rohs%20final.pdf
User-added image
 
IEC 60601-1:2005+A1 EN 60601-1:2006+A1:2013+A12:2014 IEC 60601-1-11:2015 EN 60601-1-11:2015
User-added image
 
S-Mark Certificate EN 62368-1:2014 + A11 (http://www.intertek.com/marks/s/)
User-added imageSemko S-Mark-Cert- EN60950-1
User-added image
Serial Number Information
User-added image
IEC/EN60335-1
SIQ IEC/EN 60335-1 (Safety of Household and Similar Electrical Appliances, Part 1: General Requirements) up to 36 volts
User-added image
IEC/EN61558-1
EN 61558-2-16:2009 + A1 :2013 EN 61558-1 :2005 + A 1 :2009EN 61558-2-16:2009 + A1 :2013 EN 61558-1 :2005 + A 1 :2009EN 61558-2-16:2009 + A1 :2013 EN 61558-1 :2005 + A 1 :2009EN 61558-2-16:2009 + A1 :2013 EN 61558-1 :2005 + A 1 :2009
User-added imageTransformer Symbol IEC 61558-1 SMPS Short-Circuit –Proof Safety Isolating Transformer
User-added imageTransformer Symbol IEC 61558-1 SMPS Switch Mode Power supply
User-added image
 
UKCA Certification
User-added imageUkraine UKRSepro (Document: www.globtek.com/html/iso_certificates/GT_Ukraine.pdf)
User-added imageJapan: Voluntary Control Council for Interference (VCCI)
 User-added imageWEEE: Complies with EU 2012/19/EU (http://ec.europa.eu/environment/waste/weee/index_en.htm) Mark is on the label or Molded in the case
Popular Products (Stock items)
SKUVolts OutCurrent Out (Amps)ConnectorRFQSample Request
117452224.01.25
10441465.02.0
8689265.04.0
1681819.62.6
61860712.02.5
61808112.02.5
37601412.02.5
32390212.02.5
25281727.01.0
26425512.02.5
2579635.04.0
24960212.02.5
22772812.02.5
18428412.02.5
18669812.02.5
19166518.01.66
19771448.00.625
1964999.13.3
1782079.13.3
17132724.01.25
19835813.01.3
19093815.02.0
1920579.13.3
18037744.50.67
12914212.02.5
18045124.01.25
1807469.13.3
16869712.02.5
1681395.04.0
14654024.01.25
16325830.01.0
10240212.02.5
1358167.53.0
12914312.02.5
1465375.04.0
19644512.02.5
17716913.82.17
16570848.00.0
10240748.00.0
23316013.01.3
16343015.02.0
1784119.02.77
1634289.03.3
1291395.04.0
1279925.04.0
26456412.02.5
26162124.01.25
2672675.04.0
22628415.02.0
21807915.02.0
2143055.04.0
21486919.01.57
21461512.02.5
2011929.33.2
1916369.02.8
19510112.02.5
1960299.03.3
18171815.02.0
18647324.01.25
18203030.01.0
18633513.01.3
18716612.02.5
18648413.01.3
18028412.02.5
18089848.00.625
1800949.02.77
1795535.04.0
17941124.01.25
1784125.04.0
17809112.02.5
17713715.02.0
17696815.02.0
17588024.01.25
17941012.02.5
17497212.02.5
17102124.01.25
16697530.01.0
1646745.04.0
1465365.04.0
1107556.00.0
1811819.01.0
1811806.01.0
1920535.04.0
26248912.02.5
2624775.04.0
22489224.01.3
22408015.02.0
1999439.02.8
1999429.02.8
19972124.01.3
19954812.02.5
21511412.02.5
1894136.01.5
1864459.13.3
18447118.01.7
18419212.02.5
18304112.02.5
18253012.02.5
18191612.02.5
18157812.02.5
181318
17950818.01.7
1794095.03.0
179035
27188724.01.3
19927916.01.5
61858212.02.5
17787412.02.5
17713312.02.5
17828312.02.5
17512524.01.3
17496812.02.5
17429524.01.3
17236248.00.4
17101624.01.3
17071612.02.5
16972624.01.3
1682095.02.0
1681905.04.0
1681585.04.0
1681295.04.0
1672305.04.0
1670285.04.0
16807835.04.0
156683512.02.5
91965424.01.3
17516612.02.5
Vad är ett IEC 62368-1 : 2018 power supply ? IEC 62368-1 : 2018 användas till säkerhet för elektriska och elektroniska apparater angående audio, video, information och kommunikationsteknologi, business- och kontormaskiner med en graderad spänning som ej överstiger 600V. Detta är en produktsäkerhetsstandard som klassifiserar energikällor, föreskrivna skydd mot dessa energikällor och ger information vid användning av- och krav till dessa skydd. Föreskrivna skyddskrav är menade för att minska sannolikhet för smärta, injurier och i fall av brand och egendom skador. Et IEC 62368 godkänd AC/DC power supply, är ett adapter som är testad och auktoriserad enligt bestämda standard. Ersätter ett IEC 62369-1 godkänd power supply ett IEC 60950-1 godkänd power supply ? 20 december 2020 är säkerhets- standardene IEC 60950-1 och IEC 60065 historia och ersättes av IEC 62368-1angående tekniska - och audio video produkter. I nord-Amerika vill ETL och UL 60950-1 godkanningar fortfarande existera och vill antagligen användas ytterligare. Vad är en hybrid wall plug-in / desktop AC/DC adapter ? En hybrid wall plug-in / desktop AC/DC adapter är ochså känd som AC adaptrar eller AC/DC omvandlare , och är exempel på externa power supply. Dessa enheter anses vara som en hybrid ärför att dom kan användas som standard desktop power supply där dom använder en IEC 69320 power kabel eller passande AC kontaktsystem för att användas som en wall plug-in och monteras direkt till vägguttag utan en kabel. Några elektriska enheter kräver ström, men har brist på interna komponenter för att ge önskad spänning och ström. Det är här AC adaptrar blir använd för att konvertera AC ström till DC spänning, What is the The Unique Device Identification (UDI) for my GlobTek medical grade power supply?

The Unique Device Identification (UDI) as required by the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) is required for registered medical devices. While GlobTek medical grade power supplies carry full medical certifications they're actually not considered medical devices themselves but a component of such. And therefore do not have registration with the Food and Drug Administration Amendments Act of 2007 and EU Medical Device Regulation (MDR) and therefore so not carry a The Unique Device Identification (UDI). Hur fungerar ett AC/DC adapter ? AC/DC adapteren eller exsternt power supply är bestående av ett power supply som är skyddad i ett plasthus motsvarande en AC plugg, därmed namn som plug type, wall plug-in , plug in eller plugtop adapter. Adapteren monteras i vägguttaget och
Begär information
Call
Email
💬
Text
💁
Chat
?
Begär en offert
Kan vi hjälpa dig?
Kan vi hjälpa dig?